404 research outputs found

    Mathematical analysis of super-resolution methodology

    Get PDF
    The attainment of super resolution (SR) from a sequence of degraded undersampled images could be viewed as reconstruction of the high-resolution (HR) image from a finite set of its projections on a sampling lattice. This can then be formulated as an optimization problem whose solution is obtained by minimizing a cost function. The approaches adopted and their analysis to solve the formulated optimization problem are crucial, The image acquisition scheme is important in the modeling of the degradation process. The need for model accuracy is undeniable in the attainment of SR along with the design of the algorithm whose robust implementation will produce the desired quality in the presence of model parameter uncertainty. To keep the presentation focused and of reasonable size, data acquisition with multisensors instead of, say a video camera is considered.published_or_final_versio

    Analysis of displacement errors in high-resolution image reconstruction with multisensors

    Get PDF
    An image-acquisition system composed of an array of sensors, where each sensor has a subarray of sensing elements of suitable size, has recently been popular for increasing the spatial resolution with high signal-to-noise ratio beyond the performance bound of technologies that constrain the manufacture of imaging devices. Small perturbations around the ideal subpixel locations of the sensing elements (responsible for capturing the sequence of undersampled degraded frames), because of imperfections in fabrication, limit the performance of the signal-processing algorithms for processing and integrating the acquired images for the desired enhanced resolution and quality. The contributions of this paper include an analysis of the displacement errors on the convergence rate of the iterative approach for solving the transform based preconditioned system of equations. Subsequently, it is established that the use of the MAP, L2 norm or H1 norm regularization functional leads to a proof of linear convergence of the conjugate gradient method in terms of the displacement errors caused by the imperfect subpixel locations. Results of simulation support the analytical results.published_or_final_versio

    Liprin-α4 Is Required for Nickel Induced Receptor Protein Tyrosine Phosphatase-Leukocyte Antigen Related Receptor F (RPTP-LAR) Activity

    Get PDF
    Liprin-α4 was strongly induced following nickel (II) chloride exposure in a variety of cell types including BEAS-2B, A549, BEP2D and BL41 cells. Liprin-α4, a member of the Liprin alpha family, has seven isoforms but only three of these variants were detected in BEAS-2B cells (004, 201 and 202). The level of Liprin-α4 variants 201 and 004 were highly increased in BEAS-2B cells in response to nickel. We showed that Liprin-α4 bound directly to the cytoplasmic region of RPTP-LAR (receptor protein tyrosine phosphatase-leukocyte antigen-related receptor F). The cytoplasmic region of RPTP-LAR contains two phosphatase domains but only the first domain shows activity. The second domain interacts with other proteins. The phosphatase activity was increased both following nickel treatment and also in the presence of nickel ions in cell extracts. Liprin-α4 knock-down lines with decreased expression of Liprin-α4 variants 004 and 201 exhibited greater nickel toxicity compared to controls. The RPTP-LAR phosphatase activity was only slightly increased in a Liprin-α4 knock-down line. Liprin-α4 appeared necessary for the nickel induced tyrosine phosphatase activity. The presence of Liprin-α4 and nickel increased tyrosine phosphatase activity that reduced the global levels of tyrosine phosphorylation in the cell

    Do knowledge infrastructure facilities support Evidence-Based Practice in occupational health? An exploratory study across countries among occupational physicians enrolled on Evidence-Based Medicine courses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Evidence-Based Medicine (EBM) is an important method used by occupational physicians (OPs) to deliver high quality health care. The presence and quality of a knowledge infrastructure is thought to influence the practice of EBM in occupational health care. This study explores the facilities in the knowledge infrastructure being used by OPs in different countries, and their perceived importance for EBM practice.</p> <p>Methods</p> <p>Thirty-six OPs from ten countries, planning to attend an EBM course and to a large extent recruited via the European Association of Schools of Occupational Medicine (EASOM), participated in a cross-sectional study.</p> <p>Results</p> <p>Research and development institutes, and knowledge products and tools are used by respectively more than 72% and more than 80% of the OPs and they are rated as being important for EBM practice (more than 65 points (range 0–100)). Conventional knowledge access facilities, like traditional libraries, are used often (69%) but are rated as less important (46.8 points (range 0–100)) compared to the use of more novel facilities, like question-and-answer facilities (25%) that are rated as more important (48.9 points (range 0–100)). To solve cases, OPs mostly use non evidence-based sources. However, they regard the evidence-based sources that are not often used, e.g. the Cochrane library, as important enablers for practising EBM. The main barriers are lack of time, payment for full-text articles, language barrier (most texts are in English), and lack of skills and support.</p> <p>Conclusion</p> <p>This first exploratory study shows that OPs use many knowledge infrastructure facilities and rate them as being important for their EBM practice. However, they are not used to use evidence-based sources in their practice and face many barriers that are comparable to the barriers physicians face in primary health care.</p

    Ratio of the Isolated Photon Cross Sections at \sqrt{s} = 630 and 1800 GeV

    Get PDF
    The inclusive cross section for production of isolated photons has been measured in \pbarp collisions at s=630\sqrt{s} = 630 GeV with the \D0 detector at the Fermilab Tevatron Collider. The photons span a transverse energy (ETE_T) range from 7-49 GeV and have pseudorapidity η<2.5|\eta| < 2.5. This measurement is combined with to previous \D0 result at s=1800\sqrt{s} = 1800 GeV to form a ratio of the cross sections. Comparison of next-to-leading order QCD with the measured cross section at 630 GeV and ratio of cross sections show satisfactory agreement in most of the ETE_T range.Comment: 7 pages. Published in Phys. Rev. Lett. 87, 251805, (2001

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore